The Turbine Signal Test Set (TSTS) is designed to input a turbine meter signal, display the frequency, and calculate flow rate and totals. It can also output a sine wave at a selectable frequency and amplitude. The TSTS can also output a square wave pulse scaled to a unit corrected volume (for example one pulse per MCF).
Features
- Instantaneous flow rate
- Totalizer
- Pulse output
- Programmable frequency generator
- Portable hand held weatherproof enclosure with 5’ coiled cable pickup and quick insert adapter
Specifications
Mechanical | |
---|---|
Size | 5"h x 10.8"w x 9.5"d |
Weight | 3.5 pounds without cable accessories |
Connections | Turbine meter magnetic pick-up or special cable |
Power | |
Battery | 4 x AA @ > 2000 mAh |
Environmental | |
Operating temperature | |
LCD | 32 to 122 deg. F (0 to 50 deg. C) |
Unit | -40 to 158 deg. F (-40 to 70 deg. C) |
User Interface | |
Display | 2x16 alphanumeric super twist liquid crystal |
Keypad | 16 key embedded front panel overlay |
Viewing options | Turbine input: frequency or flow rate with volume totalizer |
Sine wave generator output: level or frequency | |
Menus for programming inputs, outputs and system configurations. Power conservation feature. Pressing any key will re-activate the display. | |
Inputs | |
Type | One turbine signal |
Sensitivity | 30 mVpp to 10 Vpp with user adjustable gain settings of high (x100), medium (x16), low (x2), or any value (from x2 to x250). |
Frequency | 30 Hz to 10 kHz |
Outputs | |
Type | One sine wave generator with transformer coupling |
One non-isolated open collector transistor | |
One active pulse push pull transistor | |
Frequency | |
Sine wave generator | 30 Hz to 10 kHz |
Pulse | Frequency mode: 30 Hz to 10 kHz 50% duty cycle |
Drive | |
Sine wave generator | Transformer coupled 30 mVpp to 4 Vpp |
Pulse open collector | 250 mA @ 40 VDC common ground |
Pulse active push pull transistor | 0-5 VDC @ 20 mA |
Included
- 1- TSTS Test Set in weatherproof case
- 1- 5 foot coiled cord with magnetic pickup and quick insert adapter
- 4- AA Alkaline Batteries
Options
- AETSTS-5’-Coil-Cable AE 5’ Coiled signal cable with magnetic pick-up and donut for use with the AE TSTS (standard with new "TSTS")
- AETSTS-5’-Freq-Cable AE 5’ Mylar shielded cable w/male 2 pin connector (compatible with MC-II and similar totalizers)
NOTE: Contact factory for cables requiring special end connectors